Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
1.
Clin Res Cardiol ; 2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-38619575

RESUMEN

BACKGROUND: Transcatheter aortic valve implantation (TAVI) serves a growing range of patients with severe aortic stenosis (AS). TAVI has evolved to a streamlined procedure minimizing length of hospital stay. AIMS: To evaluate the safety and efficacy of an early discharge (ED) strategy after TAVI. METHODS: We performed an international, multi-center, prospective observational single-arm study in AS patients undergoing TAVI with the ACURATE valve platform. Eligibility for ED was assessed prior to TAVI and based on prespecified selection criteria. Discharge ≤ 48 h was defined as ED. Primary Valve Academic Research Consortium (VARC)-3-defined 30-day safety and efficacy composite endpoints were landmarked at 48 h and compared between ED and non-ED groups. RESULTS: A total of 252 patients were included. The median age was 82 [25th-75th percentile, 78-85] years and the median Society of Thoracic Surgeons Predicted Risk of Mortality (STS-PROM) score was 2.2% [25th-75th percentile, 1.6-3.3]. ED and non-ED were achieved in 173 (69%) and 79 (31%) patients respectively. Monitoring for conduction disturbances was the principal reason for non-ED (33%). Overall, at 30 days, all-cause mortality was 1%, new permanent pacemaker rate was 4%, and valve- or procedure-related rehospitalization was 4%. There was no difference in the primary safety and efficacy endpoint between the ED and non-ED cohorts (OR 0.84 [25th-75th percentile, 0.31-2.26], p = 0.73, and OR 0.97 [25th-75th percentile, 0.46-2.06], p = 0.94). The need for rehospitalization was similarly low for ED and non-ED groups. CONCLUSION: Early discharge after TAVI with the ACURATE valve is safe and feasible in selected patients. Rhythm monitoring and extended clinical observation protracted hospital stay.

2.
Artículo en Inglés | MEDLINE | ID: mdl-38448258

RESUMEN

BACKGROUND: Left atrial appendage (LAA) occluder embolization is an infrequent but serious complication. OBJECTIVES: We aim to describe timing, management and clinical outcomes of device embolization in a multi-center registry. METHODS: Patient characteristics, imaging findings and procedure and follow-up data were collected retrospectively. Device embolizations were categorized according to 1) timing 2) management and 3) clinical outcomes. RESULTS: Sixty-seven centers contributed data. Device embolization occurred in 108 patients. In 70.4 % of cases, it happened within the first 24 h of the procedure. The device was purposefully left in the LA and the aorta in two (1.9 %) patients, an initial percutaneous retrieval was attempted in 81 (75.0 %) and surgery without prior percutaneous retrieval attempt was performed in 23 (21.3 %) patients. Two patients died before a retrieval attempt could be made. In 28/81 (34.6 %) patients with an initial percutaneous retrieval attempt a second, additional attempt was performed, which was associated with a high mortality (death in patients with one attempt: 2.9 % vs. second attempt: 21.4 %, p < 0.001). The primary outcome (bailout surgery, cardiogenic shock, stroke, TIA, and/or death) occurred in 47 (43.5 %) patients. Other major complications related to device embolization occurred in 21 (19.4 %) patients. CONCLUSIONS: The majority of device embolizations after LAA closure occurs early. A percutaneous approach is often the preferred method for a first rescue attempt. Major adverse event rates, including death, are high particularly if the first retrieval attempt was unsuccessful. CONDENSED ABSTRACT: This dedicated multicenter registry examined timing, management, and clinical outcome of device embolization. Early embolization (70.4 %) was most frequent. As a first rescue attempt, percutaneous retrieval was preferred in 75.0 %, followed by surgical removal (21.3 %). In patients with a second retrieval attempt a higher mortality (death first attempt: 2.9 % vs. death second attempt: 24.1 %, p < 0.001) was observed. Mortality (10.2 %) and the major complication rate after device embolization were high.

3.
Catheter Cardiovasc Interv ; 103(2): 382-388, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38078877

RESUMEN

BACKGROUND: Evidence-based recommendations for antithrombotic treatment in patients who have an indication for oral anticoagulation (OAC) after transcatheter edge-to-edge mitral valve repair (TEER) are lacking. AIMS: To compare bleeding and thrombotic risk for different antithrombotic regimens post-TEER with MitraClip in an unselected population with the need for OACs. METHODS: Bleeding and thrombotic complications (stroke and myocardial infarction) up to 3 months after TEER with mitraclip were evaluated in 322 consecutive pts with an indication for OACs. These endpoints were defined by the Mitral Valve Academic Research Consortium criteria and were compared between two antithrombotic regimens: single antithrombotic therapy with OAC (single ATT) and double/triple ATT with a combination of OAC and aspirin and/or clopidogrel (combined ATT). RESULTS: Collectively, 108 (34%) patients received single ATT, 203 (63%) received double ATT and 11 (3%) received triple ATT. Bleeding events occurred in 67 patients (20.9%), with access site related events being the most frequent cause (37%). Bleeding complications were observed more frequently in the combined ATT group than in the single ATT group: 24% versus 14% [p = 0.03, adjusted RR: 0.55 (0.3-0.98)]. Within the combined group, the bleeding risk was 23% in the double ATT and 45% in the triple ATT group. Thrombotic complications occurred in only three patients (0.9%), and all belonged to the combined ATT group. CONCLUSIONS: In patients with an indication for OACs, withholding of antiplatelet therapy post-TEER with Mitraclip was associated with a 45% reduction in bleeding and without a signal of increased thrombotic risk.


Asunto(s)
Inhibidores de Agregación Plaquetaria , Trombosis , Humanos , Inhibidores de Agregación Plaquetaria/efectos adversos , Anticoagulantes/efectos adversos , Fibrinolíticos/efectos adversos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Resultado del Tratamiento , Hemorragia/inducido químicamente , Trombosis/etiología , Trombosis/prevención & control , Sistema de Registros
4.
EuroIntervention ; 20(6): e354-e362, 2024 Mar 18.
Artículo en Inglés | MEDLINE | ID: mdl-37982158

RESUMEN

BACKGROUND: Despite transcatheter aortic valve implantation (TAVI) having become a routine procedure, access site bleeding and vascular complications are still a concern which contribute to procedure-related morbidity and mortality. AIMS: The TAVI-MultiCLOSE study aimed to assess the safety and efficacy of a new vascular closure algorithm for percutaneous large-bore arterial access closure following transfemoral (TF)-TAVI. METHODS: All consecutive TF-TAVI cases in which the MultiCLOSE vascular closure algorithm was used were prospectively included in a multicentre, observational study. This stepwise algorithm entails the reinsertion of a 6-8 Fr sheath (primary access) following the initial preclosure with one or two suture-based vascular closure devices (VCDs). This provides the operator with the opportunity to perform a quick and easy angiographic control and tailor the final vascular closure with either an additional suture- or plug-based VCD, or neither of these. RESULTS: Among 630 patients who underwent TF-TAVI utilising the MultiCLOSE algorithm, complete arterial haemostasis was achieved in 616 patients (98%). VCD failure occurred in 14 patients (2%), treated with either balloon inflation (N=1), covered stent (N=12) or surgical repair (N=1). Overall, this vascular closure approach resulted in a minor and major vascular complication rate of 2.2% and 0.6%, respectively. At 30 days, only one new minor vascular complication (0.2%) was noted. In-hospital and 30-day all-cause mortality rates were 0.2% and 1.0%, respectively. CONCLUSIONS: Use of the MultiCLOSE vascular closure algorithm was demonstrated to contribute to an easy, safe, efficacious and durable vascular closure after TF-TAVI, resulting in a major vascular complication rate of less than 1%.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Dispositivos de Cierre Vascular , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Arteria Femoral/cirugía , Hemorragia/etiología , Hemorragia/prevención & control , Técnicas Hemostáticas/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento , Dispositivos de Cierre Vascular/efectos adversos
5.
Front Cardiovasc Med ; 10: 1161779, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37529710

RESUMEN

Paravalvular leak (PVL) is a shortcoming that can erode the clinical benefits of transcatheter valve replacement (TAVR) and therefore a readily applicable method (aortography) to quantitate PVL objectively and accurately in the interventional suite is appealing to all operators. The ratio between the areas of the time-density curves in the aorta and left ventricular outflow tract (LVOT-AR) defines the regurgitation fraction (RF). This technique has been validated in a mock circulation; a single injection in diastole was further tested in porcine and ovine models. In the clinical setting, LVOT-AR was compared with trans-thoracic and trans-oesophageal echocardiography and cardiac magnetic resonance imaging. LVOT-AR > 17% discriminates mild from moderate aortic regurgitation on echocardiography and confers a poor prognosis in multiple registries, and justifies balloon post-dilatation. The LVOT-AR differentiates the individual performances of many old and novel devices and is being used in ongoing randomized trials and registries.

6.
EuroIntervention ; 19(9): 766-771, 2023 Nov 17.
Artículo en Inglés | MEDLINE | ID: mdl-37605804

RESUMEN

About one-third of patients undergoing transcatheter aortic valve implantation (TAVI) use oral anticoagulants (OAC), mainly due to atrial fibrillation. General guidelines advise interrupting OAC in patients with a high risk of bleeding undergoing interventions. However, preliminary observational data suggest that the continuation of OAC during TAVI is safe and may reduce the risk of periprocedural thromboembolic events. The Periprocedural Continuation Versus Interruption of Oral Anticoagulant Drugs During Transcatheter Aortic Valve Implantation (POPular PAUSE TAVI) is a multicentre, randomised clinical trial with open-label treatment and blinded endpoint assessment. Patients are randomised 1:1 to periprocedural continuation versus interruption of OAC and are stratified for vitamin K antagonist or direct oral anticoagulant use. The primary endpoint is a composite of cardiovascular mortality, all stroke, myocardial infarction, major vascular complications and type 2-4 bleeding within 30 days after TAVI, according to the Valve Academic Research Consortium-3 criteria. Secondary endpoints include separate individual and composite outcomes, quality of life and cost-effectiveness. Since continuation of OAC is associated with the ancillary benefit that it simplifies periprocedural management, the primary outcome is first analysed for non-inferiority; if non-inferiority is proven, superiority will be tested. Recruitment started in November 2020, and the trial will continue until a total of 858 patients have been included and followed for 90 days. In summary, POPular PAUSE TAVI is the first randomised clinical trial to assess the safety and efficacy of periprocedural continuation versus interruption of OAC in patients undergoing TAVI.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Calidad de Vida , Anticoagulantes/uso terapéutico , Hemorragia , Resultado del Tratamiento , Válvula Aórtica/cirugía , Factores de Riesgo
7.
Front Cardiovasc Med ; 10: 1227217, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37645516

RESUMEN

Background: A steep rise in the use of transcatheter aortic valve implantation (TAVI) for the management of symptomatic severe aortic stenosis occurred. Minimalist TAVI procedures and streamlined patient pathways within experienced Heart Valve Centres are designed to overcome the challenges of ever-increasing procedural volume. Aims: The 2022 European TAVI Pathway Survey aims to describe contemporary TAVI practice across Europe. Materials and methods: Between October and December 2022, TAVI operators from 32 European countries were invited to complete an online questionnaire regarding their current practice. Results: Responses were available from 147 TAVI centres in 26 countries. In 2021, the participating centres performed a total number of 27,223 TAVI procedures, with a mean of 185 TAVI cases per centre (median 138; IQR 77-194). Treatment strategies are usually (87%) discussed at a dedicated Heart Team meeting. Transfemoral TAVI is performed with local anaesthesia only (33%), with associated conscious sedation (60%), or under general anaesthesia (7%). Primary vascular access is percutaneous transfemoral (99%) with secondary radial access (52%). After uncomplicated TAVI, patients are transferred to a high-, medium-, or low-care unit in 28%, 52%, and 20% of cases, respectively. Time to discharge is day 1 (12%), day 2 (31%), day 3 (29%), or day 4 or more (28%). Conclusion: Reported adoption of minimalist TAVI techniques is common among European TAVI centres, but rates of next-day discharge remain low. This survey highlights the significant progress made in refining TAVI treatment and pathways in recent years and identifies possible areas for further improvement.

8.
JACC Cardiovasc Interv ; 16(6): 655-666, 2023 03 27.
Artículo en Inglés | MEDLINE | ID: mdl-36990554

RESUMEN

BACKGROUND: When performing transcatheter left atrial appendage (LAA) closure, peridevice leaks and device-related thrombus (DRT) have been associated with worse clinical outcomes-hence, their risk should be mitigated. OBJECTIVES: The authors sought to assess whether use of preprocedural computational modeling impacts procedural efficiency and outcomes of transcatheter LAA closure. METHODS: The PREDICT-LAA trial (NCT04180605) is a prospective, multicenter, randomized trial in which 200 patients were 1:1 randomized to standard planning vs cardiac computed tomography (CT) simulation-based planning of LAA closure with Amplatzer Amulet. The artificial intelligence-enabled CT-based anatomical analyses and computer simulations were provided by FEops (Belgium). RESULTS: All patients had a preprocedural cardiac CT, 197 patients underwent LAA closure, and 181 of these patients had a postprocedural CT scan (standard, n = 91; CT + simulation, n = 90). The composite primary endpoint, defined as contrast leakage distal of the Amulet lobe and/or presence of DRT, was observed in 41.8% in the standard group vs 28.9% in the CT + simulation group (relative risk [RR]: 0.69; 95% CI: 0.46-1.04; P = 0.08). Complete LAA closure with no residual leak and no disc retraction into the LAA was observed in 44.0% vs 61.1%, respectively (RR: 1.44; 95% CI: 1.05-1.98; P = 0.03). In addition, use of computer simulations resulted in improved procedural efficiency with use of fewer Amulet devices (103 vs 118; P < 0.001) and fewer device repositionings (104 vs 195; P < 0.001) in the CT + simulation group. CONCLUSIONS: The PREDICT-LAA trial demonstrates the possible added value of artificial intelligence-enabled, CT-based computational modeling when planning for transcatheter LAA closure, leading to improved procedural efficiency and a trend toward better procedural outcomes.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Humanos , Estudios Prospectivos , Apéndice Atrial/diagnóstico por imagen , Inteligencia Artificial , Resultado del Tratamiento , Simulación por Computador , Cateterismo Cardíaco/efectos adversos , Ecocardiografía Transesofágica
10.
Cardiovasc Revasc Med ; 44: 71-77, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35739011

RESUMEN

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is now an established treatment strategy for elderly patients with symptomatic aortic stenosis (AS) across the entire operative risk spectrum. Streamlined TAVR protocols along with reduced procedure time and expedited ambulation promote early hospital discharge. Selection of patients suitable for safe early discharge after TAVR might improve healthcare efficiency. STUDY DESIGN: The POLESTAR trial is an international, multi-center, prospective, observational study which aims to evaluate the safety of early discharge in selected patients who undergo TAVR with the supra-annular functioning self-expanding ACURATE Neo transcatheter heart valve (THV). A total of 250 patients will be included based on a set of baseline criteria indicating potential early discharge (within 48 h post-TAVR). Primary study endpoints include Valve Academic Research Consortium (VARC)-3 defined safety at 30 days and VARC-3 defined efficacy at 30 days and 1 year. Endpoints will be compared between early discharge and non-early discharge cohorts with a distinct landmark analysis at 48 h post-TAVR. Secondary endpoints include quality of life assessed using EQ5D-5L and Kansas City Cardiomyopathy Questionnaire (KCCQ) questionnaires and resource costs compared between discharge groups. SUMMARY: The POLESTAR trial prospectively evaluates safety and feasibility of an early discharge protocol for TAVR using the ACURATE Neo THV.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Anciano , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Calidad de Vida , Estudios Prospectivos , Alta del Paciente , Diseño de Prótesis , Resultado del Tratamiento , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Factores de Riesgo
11.
Am Heart J ; 246: 32-43, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-34990582

RESUMEN

BACKGROUND: Current ESC guidelines recommend the use of intra-coronary pressure guidewires for functional assessment of intermediate-grade coronary stenoses. Angiography-derived quantitative flow ratio (QFR) is a novel method of assessing these stenoses, and guiding percutaneous coronary intervention (PCI). METHODS/DESIGN: The PIONEER IV trial is a prospective, all-comers, multi-center trial, which will randomize 2,540 patients in a 1:1 ratio to PCI guided by angiography-derived physiology or usual care, with unrestricted use in both arms of the Healing-Targeted Supreme sirolimus-eluting stent (HT Supreme). The stent's fast, biologically healthy, and robust endothelial coverage allows for short dual-antiplatelet therapy (DAPT); hence the antiplatelet regimen of choice is 1-month DAPT, followed by ticagrelor monotherapy. In the angiography-derived physiology guided arm, lesions will be functionally assessed using on-line QFR, with stenting indicated in lesions with a QFR ≤0.80. Post-stenting, QFR will be repeated in the stented vessel(s), with post-dilatation or additional stenting recommended if the QFR<0.91 distal to the stent, or if the delta QFR (across the stent) is >0.05. Usual care PCI is performed according to standard clinical practice. The primary endpoint is a non-inferiority comparison of the patient-oriented composite endpoint (POCE) of all-cause death, any stroke, any myocardial infarction, or any clinically, and physiologically driven revascularization with a non-inferiority risk-difference margin of 3.2%, at 1-year post-procedure. Clinical follow-up will be up to 3 years. SUMMARY: The PIONEER IV trial aims to demonstrate non-inferiority of QFR-guided PCI to usual care PCI with respect to POCE at 1-year in patients treated with HT Supreme stents and ticagrelor monotherapy. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov UNIQUE IDENTIFIER: NCT04923191 CLASSIFICATIONS: Interventional Cardiology.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/terapia , Humanos , Intervención Coronaria Percutánea/métodos , Estudios Prospectivos , Stents , Ticagrelor/uso terapéutico , Resultado del Tratamiento
12.
Ir J Med Sci ; 191(2): 777-784, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33895965

RESUMEN

INTRODUCTION: General practice has a key role in diagnosing patients with valvular heart disease (VHD) and referring them to appropriate services. METHODS: An anonymous survey was conducted to assess the knowledge and clinical practice behaviour of Irish general practitioners (GPs) in relation to VHD. In addition to demographic data, the survey captured information in the following domains: knowledge of VHD prevalence, knowledge of contemporary VHD treatments, barriers to diagnosis, and referral patterns. To augment responses, a monetary prize (donated to charity) was offered and the survey was also disseminated using social media and by the Irish College of General Practitioners. RESULTS: Valid survey responses were received from 197 GPs. The sample was well-balanced by gender, number of years in practice, and practice setting. A small proportion of GPs (16.8%) used a stethoscope to examine for VHD in all patients over 60 years, a figure that rose to 22.3% in patients over 75. Approximately half of participants (48%) felt confident in their ability to detect and diagnose VHD using a stethoscope, and 74% felt lack of access to echocardiography was a major barrier to making a VHD diagnosis. There was a high level of awareness among GPs of minimally invasive nonsurgical interventions now available for VHD treatment. DISCUSSION: Irish GPs displayed good understanding of contemporary VHD treatment options but reported low confidence and inconsistent practices in evaluating patients for VHD. Improved access to echocardiography might help address these deficiencies, but reorganisation of services will be required in a resource-limited public health service.


Asunto(s)
Medicina General , Médicos Generales , Enfermedades de las Válvulas Cardíacas , Enfermedades de las Válvulas Cardíacas/diagnóstico , Enfermedades de las Válvulas Cardíacas/terapia , Humanos , Derivación y Consulta , Encuestas y Cuestionarios
13.
Glob Heart ; 16(1): 54, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34381675

RESUMEN

Objectives: We aimed to compare the quantitative angiographic aortic regurgitation (AR) into the left ventricular out flow tract (LVOT-AR) of five different types of transcatheter self-expanding valves and to investigate the impact of the learning curve on post-TAVR AR. Background: Quantitative video densitometric aortography is an objective, accurate, and reproducible tool for assessment of AR following TAVR. Methods and results: This retrospective academic core-lab analysis, analyzed 1150 consecutive cine aortograms performed immediately post-TAVR. Quantitative angiographic AR of post-procedural aortography in 181 consecutive patients, who underwent TAVR with the Venus A-valve in a single Chinese center, were compared to the results of Evolut Pro, Evolut R, CoreValve, (Medtronic, Dublin, Ireland) and Acurate Neo (Boston Scientific, Massachusetts, US) transcatheter heart valves (THVs), from a previously published pooled database. Among the 181 aortograms of patients treated with the Venus A-Valve, 113 (62.4%) were analyzable for quantitative assessment of AR. The mean LVOT-AR was 8.9% ± 10.0% with 14.2% of patients having moderate or severe AR in the Venus A-valve group. No significant difference in mean LVOT-AR was observed between Evolut Pro, Evolut R, Acurate Neo, and Venus A-valve. The incidence of LVOT-AR >17%, which correlates with echocardiographic derived ≥ moderate AR, with the Evolut Pro was lower than with the Venus A-valve (5.3% vs. 14.2%, p = 0.034), but was not different from the Evolut R (5.3% vs. 8.8%, p = 0.612), or the Acurate Neo (5.3% vs. 11.3% p = 0.16) systems. A landmark analysis after recruitment of the first half of patients treated with the Venus A valve (N = 56), showed a significantly lower mean LVOT-AR in the second half of the series (11.3% ± 11.9% vs. 6.5% ± 7.1%, p = 0.011). The incidence of LVOT-AR >17% in the latest 57 cases was also numerically lower (7.0% vs. 21.4%, p = 0.857) and compared favorably with the best in class of the self-expanding valves. Conclusion: The Venus A-valve has comparable mean LVOT-AR to other self-expanding valves but has a higher rate of moderate or severe AR than the Evolut Pro THV. However, after completion of a learning phase, results improved and compared favorably with the best in class of the commercially available self-expanding valves. These findings should be confirmed in prospective randomized comparisons of AR between different THVs.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/epidemiología , Insuficiencia de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/cirugía , China/epidemiología , Humanos , Curva de Aprendizaje , Estudios Prospectivos , Diseño de Prótesis , Estudios Retrospectivos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
14.
JACC Cardiovasc Interv ; 14(14): 1523-1534, 2021 07 26.
Artículo en Inglés | MEDLINE | ID: mdl-34217623

RESUMEN

OBJECTIVES: This study aimed to validate a dedicated software for quantitative videodensitometric angiographic assessment of mitral regurgitation (QMR). BACKGROUND: Quantitative videodensitometric aortography of aortic regurgitation using the time-density principle is a well-documented technique, but the angiographic assessment of mitral regurgitation (MR) remains at best semi-quantitative and operator dependent. METHODS: Fourteen sheep underwent surgical mitral valve replacement using 2 different prostheses. Pre-sacrifice left ventriculograms were used to assess MR fraction (MRF) using QMR and MR volume (MRV). In an independent core lab, the CAAS QMR 0.1 was used for QMR analysis. In vitro MRF and MRV were assessed in a mock circulation at a comparable cardiac output to the in vivo one by thermodilution. The correlations and agreements of in vitro and in vivo MRF, MRV, and interobserver reproducibility for QMR analysis were assessed using the averaged cardiac cycles (CCs). RESULTS: In vivo derived MRF by QMR strongly correlated with in vitro derived MRF, regardless of the number of the CCs analyzed (best correlation: 3 CCs y = 0.446 + 0.994x; R = 0.784; p =0.002). The mean absolute difference between in vitro derived MRF and in vivo derived MRF from 3 CCs was 0.01 ± 4.2% on Bland-Altman analysis. In vitro MRV and in vivo MRV from 3 CCs were very strongly correlated (y = 0.196 + 1.255x; R = 0.839; p < 0.001). The mean absolute difference between in vitro MRV and in vivo MRV from 3 CCs was -1.4 ± 1.9 ml. There were very strong correlations of in vivo MRF between 2 independent analysts, regardless of the number of the CCs. CONCLUSIONS: In vivo MRF using the novel software is feasible, accurate, and highly reproducible. These promising results have led us to initiate the first human feasibility study comprising patients undergoing percutaneous mitral valve edge-to-edge repair.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Insuficiencia de la Válvula Mitral , Animales , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/cirugía , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Prótesis e Implantes , Reproducibilidad de los Resultados , Ovinos , Resultado del Tratamiento
15.
Int J Cardiol ; 338: 168-173, 2021 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-34147554

RESUMEN

BACKGROUND: Appropriate size selection of transcatheter heart valves (THVs) is fundamental to reduce transcatheter aortic valve implantation (TAVI) related complications, particularly paravalvular aortic regurgitation, new permanent pacemaker implantation, and annular rupture. We sought to investigate the frequency of operator selection of intermediate-size balloon-expandable Myval THVs (Meril Life Sciences Pvt. Ltd., India) for TAVI in a real-world dataset. METHODS: In this retrospective survey of patients treated with TAVI using the Myval THV, 20, 23, 26, and 29 mm are conventional-size THVs, 21.5, 24.5 and 27.5 mm are intermediate-size THVs, and 30.5 and 32 mm are extra-large THVs. Operator size selection for implantation was based on multislice computed tomography (MSCT) derived aortic-root dimensions. RESULTS: A total of 1115 patients underwent Myval THV implantation in 27 countries worldwide. The Myval intermediate-size THVs were used in 468 (42.0%) patients. MSCT data were available in 562 patients. There was no statistical difference between the Intermediate/Upsized and Appropriately sized groups or Intermediate/Downsized and Appropriately sized groups in terms of different variables measured with MSCT except for annular dimensions and degree of calcification. CONCLUSIONS: Intermediate-size Myval balloon-expandable THVs are used in nearly half of all cases in contemporary real-world TAVI practice, addressing the unmet need of TAVI operators for a more calibrated THV choice. Our hypothesis should be tested in randomized prospective studies currently initiated in Europe, including clinical outcomes of patients treated with both conventional- and intermediate-size THVs.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Europa (Continente) , Humanos , India , Estudios Prospectivos , Diseño de Prótesis , Estudios Retrospectivos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
16.
BMJ Open ; 11(4): e045590, 2021 04 02.
Artículo en Inglés | MEDLINE | ID: mdl-33811055

RESUMEN

AIMS: To evaluate temporal trends of acute coronary syndromes (ACS) treated via percutaneous coronary intervention (PCI) throughout the COVID-19 outbreak in a European healthcare system affected but not overwhelmed by COVID-19-related pathology. METHODS AND RESULTS: We performed a retrospective multicentre analysis of the rates of PCI for the treatment of ACS within the period 2 months pre and post the first confirmed COVID-19 case in Ireland, as well as comparing PCI for ST-elevation myocardial infarction (STEMI) with the corresponding period in 2019. During the 2020 COVID-19 period (29 February-30 April 2020), there was a 24% decline in PCI for overall ACS (incidence rate ratio (IRR) 0.76; 95% CI 0.65 to 0.88; p<0.001), including a 29% reduction in PCI for non-ST-elevation ACS (IRR 0.71; 95% CI 0.57 to 0.88; p=0.002) and an 18% reduction in PCI for STEMI (IRR 0.82; 95% CI 0.67 to 1.01; p=0.061), as compared with the 2020 pre-COVID-19 period (1 January-28 February 2020). A 22% (IRR 0.78; 95% CI 0.65 to 0.93; p=0.005) reduction of PCI for STEMI was seen as compared with the 2019 reference period. CONCLUSION: This study demonstrates a significant reduction in PCI procedures for the treatment of ACS since the COVID-19 outbreak in Ireland. The reasons for this decline are still unclear but patients need to be encouraged to seek medical attention when cardiac symptoms appear, in order to avoid incremental cardiac morbidity and mortality due to a reduction in coronary revascularisation for the treatment of ACS.


Asunto(s)
Síndrome Coronario Agudo , COVID-19/epidemiología , Intervención Coronaria Percutánea/estadística & datos numéricos , Síndrome Coronario Agudo/epidemiología , Síndrome Coronario Agudo/cirugía , Atención a la Salud , Humanos , Irlanda/epidemiología , Pandemias , Estudios Retrospectivos , Resultado del Tratamiento
17.
JACC Cardiovasc Interv ; 14(5): 531-538, 2021 03 08.
Artículo en Inglés | MEDLINE | ID: mdl-33582086

RESUMEN

OBJECTIVES: The aim of this study was to investigate the online assessment feasibility of aortography using videodensitometry in the catheterization laboratory during transcatheter aortic valve replacement (TAVR). BACKGROUND: Quantitative assessment of regurgitation after TAVR through aortography using videodensitometry is simple, reproducible, and validated in vitro, in vivo, in clinical trials, and in "real-world" patients. However, thus far the assessment has been done offline. METHODS: This was a single center, prospective, proof-of-principle, feasibility study. One hundred consecutive patients with aortic stenosis and indications to undergo TAVR were enrolled. All final aortograms were analyzed immediately after acquisition in the catheterization laboratory and were also sent to an independent core laboratory for blinded offline assessment. The primary endpoint of the study was the feasibility of the online assessment of regurgitation (percentage of analyzable cases). The secondary endpoint was the reproducibility of results between the online assessment and the offline analysis by the core laboratory. RESULTS: Patients' mean age was 81 ± 7 years, and 56% were men. The implanted valves were either SAPIEN 3 (97%) or SAPIEN 3 Ultra (3%). The primary endpoint of online feasibility of analysis was 92% (95% confidence interval [CI]: 86% to 97%) which was the same feasibility encountered by the core laboratory (92%; 95% CI: 86% to 97%). Reproducibility assessment showed a high correlation between online and core laboratory evaluations (R2 = 0.87, p < 0.001), with an intraclass correlation coefficient of 0.962 (95% CI: 0.942 to 0.975; p < 0.001). CONCLUSIONS: This study showed high feasibility of online quantitative assessment of regurgitation and high agreement between the online examiner and core laboratory. These results may pave the way for the application of videodensitometry in the catheterization laboratory after TAVR. (Online Videodensitometric Assessment of Aortic Regurgitation in the Cath-Lab [OVAL]; NCT04047082).


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Aortografía , Estudios de Factibilidad , Humanos , Masculino , Estudios Prospectivos , Diseño de Prótesis , Reproducibilidad de los Resultados , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
18.
JACC Cardiovasc Interv ; 14(2): 172-181, 2021 01 25.
Artículo en Inglés | MEDLINE | ID: mdl-33478633

RESUMEN

OBJECTIVES: The aim of this study was to evaluate the short-term safety and efficacy of transcatheter aortic valve replacement (TAVR) with the LOTUS Edge system. BACKGROUND: The LOTUS Edge system was commercially re-released in April 2019. The authors report the first European experience with this device. METHODS: A multicenter, single-arm, retrospective registry was initiated to evaluate short-term clinical outcomes. Included cases are the first experience with this device and new implantation technique in Europe. Clinical, echocardiographic, and computed tomographic data were analyzed. Endpoints were defined according to Valve Academic Research Consortium-2 and were site reported. RESULTS: Between April and November 2019, 286 consecutive patients undergoing TAVR with the LOTUS Edge system at 18 European centers were included. The mean age and Society of Thoracic Surgeons score were 81.2 ± 6.9 years and 5.2 ± 5.4%, respectively. Nearly one-half of all patients (47.9%) were considered to have complex anatomy. Thirty-day major adverse events included death (2.4% [n = 7]) and stroke (3.5% [n = 10]). After TAVR, the mean aortic valve area was 1.9 ± 0.9 cm2, and the mean transvalvular gradient was 11.9 ± 5.7 mm Hg. None or trace paravalvular leak (PVL) occurred in 84.4% and moderate PVL in 2.0%. There were no cases of severe PVL. New permanent pacemaker (PPM) implantation was required in 25.9% among all patients and 30.8% among PPM-naive patients. CONCLUSIONS: Early experience with the LOTUS Edge system demonstrated satisfactory short-term safety and efficacy, favorable hemodynamic data, and very low rates of PVL in an anatomically complex cohort. New PPM implantation remained high. Further study will evaluate if increasing operator experience with the device and new implantation technique can reduce the incidence of PPM implantation.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Europa (Continente) , Humanos , Diseño de Prótesis , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...